Sign In | Join Free | My china-telecommunications.com
China Chongqing Bio Newvision Medical Equipment Ltd. logo
Chongqing Bio Newvision Medical Equipment Ltd.
Build Ophthalmic Equipment Flag Exploit Dignosis New Era
Verified Supplier

5 Years

Home > Optical Coherence Tomography Machine >

Class I Optical Coherence Tomography Device Continuous Operation Medical Electrical

Chongqing Bio Newvision Medical Equipment Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Class I Optical Coherence Tomography Device Continuous Operation Medical Electrical

  • 1
  • 2

Brand Name : SYSEYE

Model Number : RetiView 500

Certification : TUV

Place of Origin : China

MOQ : 1

Price : $18,500.00-$21,900.00

Payment Terms : T/T

Supply Ability : 100

Delivery Time : 5 working days

Packaging Details : 497 mm × 395 mm × 490 mm (L × W × H) 34 kg (75 lbs)

product name : Posterior Segment Optical Coherence Tomography Machine

Transverse resolution : ≤20 µm (in tissue)

Axial resolution : ≤6 µm (in tissue)

Scan depth : ≥2.5 mm (in air)

Focus adjustment : -15D to +15D

Fuse : T2AL250V

Rated power supply : AC 100V~240V、50/60Hz

Contact Now

optical coherence tomography device Class I Continuous Operation Medical Electrical Equipment

The design of the Retiview 500 complies with the EMC standard IEC 60601-1-2 for medical electrical equipment. The installation and use of the device must comply with the following EMC statement.

Optical Coherence Tomography Machine (OCT) USES frequency domain optical coherence tomography (SD-OCT) to obtain three-dimensional tomography images of the posterior segment of the eye. Sd-oct is based on low-coherent optical interferometry. In SD-OCT, light from a low-coherence source is divided by the interferometer into a sampling path (into the eye) and a reference path. The beam returning from both paths passes through the interferometer and mixes to the spectrometer. The spectrometer detects the mixed spectrum of all frequencies at the same time, and the Fourier transform of this spectrum can be used to obtain the intensity of the light signal backscattered at different depths. Since different tissues have different backscattering rates, the optical signal contains the structural information of retinal tissues. The 3d tomographic images of the retina can be obtained by transverse scanning and reconstruction of the acquired signals.

Specifications of Optical Coherence Tomography Machine

Methodology Spectral domain OCT
Axial resolution ≤6 µm (in tissue)
Transverse resolution ≤20 µm (in tissue)
Scan depth ≥2.5 mm (in air)
Scan range ≥6 mm
Scan speed ≥24,000 A-scans/sec, up to 36,000 A-scans/sec
Scan modes 3D, Raster, Circle
Fundus image OCT en face
Focus adjustment -15D to +15D
Pupil diameter ≥3 mm
OCT light source 840 nm SLD
Optical power 750 µW (at cornea)
Operation 13.3” touch screen, optional external mouse or keyboard 100-240 V, 50/60 Hz
Power supply 497 mm × 395 mm × 490 mm (L × W × H)
Dimensions Weight 34 kg (75 lbs)

Compact Design

Features:

1. Compact Design: Everything is inside this compact body. No external computer is needed. Plug in the power cable, then you are ready to go.
2. PC Inside: Data acquisition and processing are accomplished by the internal computer. The data can be transported via ethernet or external harddrive. Peripheral devices, such as keyboard or printer, can be connected to the computer ports.
3. Easy Installation:No complex connection or setup. Compact body can fit in even small space.

Optical Coherence Tomography Machine has never been so affordable. More people can benefit from the advanced technology now.

The Retiview 500 uses RF frequency energy only for its internal functions. Therefore.its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.

Class I Optical Coherence Tomography Device Continuous Operation Medical ElectricalClass I Optical Coherence Tomography Device Continuous Operation Medical Electrical

Company Introduction

Class I Optical Coherence Tomography Device Continuous Operation Medical Electrical

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Class I Optical Coherence Tomography Device Continuous Operation Medical Electrical


Product Tags:

Class I Optical Coherence Tomography Device

      

Continuous Operation Coherence Tomography Device

      

Electrical Optical Coherence Tomography Device

      
Quality Class I Optical Coherence Tomography Device Continuous Operation Medical Electrical for sale

Class I Optical Coherence Tomography Device Continuous Operation Medical Electrical Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Chongqing Bio Newvision Medical Equipment Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)